FlexxPump 125 DLS

controlled, minimal quantity lubrication for oil

  • automatic relubrication unit for 24 V DC
  • single- or multiple point lubricatior
  • compact piston-pump (1 pump body)
  • 1 outlet G1/4(o) and M6(i)
  • up to 10 lubrication-points by using distributors
  • pressure: 12 / 50 bar (switchable)
  • 125 cc / 250 cc oil in cartridge
  • low weight; running time and quantity per cycle adjustable
  • suitable for single or combined relubrication of:
    + bearings
    + linear guidance
    + ball screw
    + racks & pinions
    + rotary joints

 

 

 

.

 

 

 

 

 

.

 

.

Learn more …

Technical specifications

Technical specifications

dimensions:   83 x 152 / 188 x 83 [mm] w x h x d
weight (without lubricant):   approx. 0.35kg
function/principle:   piston pump
volume of lubricant:   125 / 250 cc (in cartridge)
delivered volume per stroke / pulse:  0.15 cc per outlet
number of pump hubs per
cartridge 125 / 250 cc:   approx. 830 / 1660
operation pressure:   12 / 50 bar (switchable)
lubricant:   oil
operating temperature:   -10°C…+70°C
number of outlets: 1
tread of outlet:   G1/4“ (o) and M6 (i)
number of lubrication points:   max. 4* / 10 **
tube-connection:   PA-tube
operating voltage:   24 V DC (via cable)
connecting plug:   M12 x 1, 4-pin
current consumption at 24 V DC:   Imax. 350 mA
installation:   rear side M5(i) (2x) or bottom side M5(i)
  with G1/4“(o) or DLS accessories
installation position:   vertical, cartridge upside
control:   integrated, microelectronic PLC
  (# 135-125-210)
running-time:   1 up to 36 months (#135-125-100)
max. quantity per cycle:   1.50 cc
pressure monitoring:   integrated, electronic
fi ll level monitoring:   integrated, electronic
error-signal:   optical, shown at LCD;
  control PLC
reset after error-signal:   (# 135-125-210) PLC
fi lling-function:   available
IP class:   IP 54
material housing:    PA 6.6-GF 30 / POM

 

Type overview

Type overview FlexxPump 125

variants

lubricant

type FlexxPump

number of outlets

number of
twin-pumpbodies

number of lubrication
points

M12x1
plug

part-No.

24V DC
time-controlled

oil

125

1

1

max. 4*/10**

++

135-125-100

24V DC
pulse-controlled

125 DLS

1

1

max. 4*/10**

++

135-125-210

* by using splitters

** more lubrication-points by using progressive-distributor.